Images consistent with Gaskets, Carburator, Mechanical, Gasket, Grommet, Silicon, Nitrile, Rubber, Ring, Neoprene, Custom and Metal.

 

Summary of Gaskets, Carburator, Mechanical, Gasket, Grommet, Silicon, Nitrile, Rubber, Ring, Neoprene, Custom, Metal

nitrile sheet

nitrile sheetFabric-Reinforced Diaphragms Offer:

  • Positive Seal
  • Low Spring Rate
  • No Lubrication
  • No Breakaway Force
  • No Friction
  • High Strength
  • Functionality Over Wide Pressure Ranges
  • Low Cost
  • Simple Design
  • Versatility
  • Therefore, nitrile sheet is widely used for many applications.

Permeation of multifunctional acrylates through selected protective glove materials.

Source

Risk Reduction Engineering Laboratory, United States Environmental Protection Agency, Edison, NJ 08837.

Abstract

In support of the Premanufacture Notification (PMN) program of the Environmental Protection Agency's Office of Toxic Substances, the resistance of three glove materials to permeation by multifunctional acrylate compounds was evaluated through a program for the Office of Research and Development. Several recent PMN submissions relate to multifunctional acrylates and essentially no permeation data are available for this class of compounds. To better understand permeation behavior, tests were conducted with trimethylolpropane triacrylate (TMPTA), 1,6-hexanediol diacrylate (HDDA), and two mixtures of HDDA with 2-ethylhexyl acrylate (EHA). Because of the low vapor pressure and low water solubility of these compounds, the tests were conducted by using ASTM Method F739-85 with a silicone rubber sheeting material as the collection medium. Tests were performed at 20 degrees C with butyl, natural, and nitrile rubber glove materials. None of the acrylate compounds nor mixtures was found to permeate the butyl or nitrile rubber under the test conditions. Permeation through the natural rubber was observed in tests with pure HDDA, a 50% HDDA/50% EHA mixture, and a 25% HDDA/75% EHA mixture. TMPTA permeation through the natural rubber was also detected, but only in one of the triplicate tests after the 360-480 min sampling interval. For pure HDDA, the breakthrough detection time was 30-60 min and the steady-state permeation rate was 0.92 micrograms/cm2-min. For the HDDA/EHA mixtures, permeation of both mixture components was detected during the same sampling interval in each test. The breakthrough detection time was 30-60 min for the 50/50 mixture and from 15-30 to 30-60 min for the 25/75 mixture.(

 

 

 

 

Dia•Com is a leading international provider of innovative, cost-effective molded diaphragm and nitrile sheet solutions critical to the operation of essential systems and equipment in industrial, automotive, aerospace, medical instrumentation, and food and water processing applications. The company's reputation for excellence is based on superior quality in the design, manufacture and application of its high-performance, state-of-the-art, fabric-reinforced and homogeneous elastomeric diaphragm seals.

about products | rubber to metal bonding | elastomeric teflon diaphragms | general hardware | diaphragm life design
bead and groove design | standard diaphragms | fabric reinforced diaphragms | homogeneous diaphragms
fab•air industrial diaphragms

home | diaphragm products | elastomer & fabric diaphragm data | diaphragm engineering | diaphragm markets
diaphragm software | about | quality | download catalog | news & events | contact | diaphragm glossary | inquiry | sitemap

Diagram of Gaskets, Carburator, Mechanical, Gasket, Grommet, Silicon, Nitrile, Rubber, Ring, Neoprene, Custom, Metal, Accumulator Diaphragm, Diaphragm Metering Pump, EPDM Gaskets, Molded Gaskets, Rubber Gaskets and Seals.
web development